| A-b
: |
If
you are using the PAD-2B 9-pin serial IR adapter |
| 1)
|
Is the PAD-2B cable connected
securely to your computer's serial port?
Firmly but gently push the connector into the port to make sure it
is plugged in as far as it will go. |
|
2)
|
Use the following procedure
to check the port number where the IR adapter is connected and the
IR transceiver name. |
 |
 |
|
1. |
Select [ Start ]
[ Settings ]
[ Control Panel ]. |
| 2.
|
Double-click the [System] icon. |
| 3.
|
Select the [Hardware] tab. |
| 4.
|
Click the [Device Manager] button.
|
| 5.
|
In the Device Manager list, double-click
[IR Devices]. |
| 6.
|
In the [IR Devices] list, double-click
"ESI-9680 JetEye Serial Infrared Device". |
| 7.
|
Select the [IrDA Settings] tab. |
| 8.
|
For [COM Port], specify the COM port
where the IR adapter is connected. |
|
|
3)
|
Check the settings
of your computer's COM port.
If your computer has both a built-in IR port and modem, its COM port
may be disabled. Use the following procedure to check your computer's
COM port setting. |
 |
 |
1.
|
Select [ Start ]
[ Settings ]
[ Control Panel ]. |
| 2.
|
Double-click the [System] icon. |
| 3.
|
Select the [Hardware] tab. |
4.
|
Click the [Device Manager] button.
|
|
5.
|
In the Device Manager list, double-click
[Ports (COM & LPT)], and look at the port number where
the PAD-2B is connected. If [Communications Port (COM1)]
is indicated, it means that the COM port number is COM1. There
may be multiple COM port numbers indicated. |
|
| 4)
|
Check your special utility/BIOS
setup.
If your computer has a special utility for changing the BIOS setup,
you may need to use the special utility to change your serial port
(COM port) settings. If you have such a computer, you should use the
setup screen of your special utility to change the setting of the
built-in IrDA port from "Disabled" to "Enabled."
The actual procedure you should use to check and change the setting
depends on your computer model. See the documentation that came with
your computer or contact the manufacturer of your computer for more information.. |
 |
 |
 |
|
 |
 |
| A-c
: |
If you are using
the PAD-5 USB IR adapter |
| 1) |
Is the PAD-5 cable connected
securely to your computer's USB port?
Firmly but gently push the connectors into the IR adapter and computer
ports to make sure they are plugged in as far as they will go. |
| 2) |
Use the following procedure
to make sure that the PAD-5 driver is correctly installed on your
computer. |
| 1.
|
Select [ Start ]
[ Settings ]
[ Control Panel ]. |
| 2.
|
Double-click the [System] icon. |
| 3.
|
Select the [Hardware] tab. |
| 4.
|
Click the [Device Manager] button.
|
| 5.
|
In the Device Manager list, double-click
[IR Devices]. |
|
6.
|
If you can see "CASIO PAD-5" under
[IR Devices], it means the PAD-5 driver is installed correctly.
If you cannot see "CASIO PAD-5" under [IR Devices],
or if there is a "?" or "!" mark next to
"CASIO PAD-5", it means the PAD-5 driver is not installed
correctly. |
|
7.
|
In this case, uninstall the current PAD-5
driver and then re-install it.
(1) Delete the file C:\WINNT\SYSTEM32\DRIVERS\STIRUSB.SYS.
(2) Delete "CASIO PAD-5" from Device Manager's
[IR Devices]. |
|
 |
 |
|
 |
 |
|
[B] If you cannot communicate at all |
| 1)
|
Check the status
of the Wrist Camera.
Your Wrist Camera must be in the "REMOTE" IR COM mode to
perform data communication with a computer. Is "REMOTE"
shown on the display of your Wrist Camera?
Also, note that your Wrist Camera will not enter the IR COM mode if
its battery is low. If you suspect this might be the cause of the
problem, try replacing the battery with a new one. |
|
2)
|
Is some other application
using your computer's IR port or serial port?
Data communication using WQV Link 3.0 software will not be possible
if your IR port is set up for data communication for a PDA link application
(such as ActiveSync for Windows CE), even if that application is not
currently running. In this case, you need to disable use of the IR
data port for by the application that is occupying it.
If you are using the PAD-2B 9-pin serial IR adapter, any PDA link,
digital camera link, fax, MIDI, or other similar application software
or driver occupying a port may issue interrupts that make it impossible
for the WQV Link 3.0 software to run properly. In this case, you need
to disable use of serial port by the application that is occupying
it. |
Important!
After you set up a COM port for the PAD-2B IR
adapter, other application software that uses the same COM port may
not operate properly even after you disconnect the PAD-2B IR adapter.
If this happens, open the Control Panel's [IR Monitor], click the
[Options] tab, and then uncheck the "Enable IR Communication"
option. In this case, you will have to select (check) the "Enable
IR Communication" option again when you want to use the WQV Link
3.0 software. |
| 3)
|
Put the Wrist Camera in
the "REMOTE" IR COM mode and then position the Wrist Camera's
IR port so it is close to the computer's IR port.
If there is a "Wireless Link" icon on your Windows 2000
taskbar, it means that your IR driver is installed correctly. If there
is no response at all, it may mean that the IR driver is not installed
correctly. Perform the steps under "Check this first." If
those do not work, try re-installing the driver. |
 |
 |
|
 |
 |
| [C] If data communication stops part way through or is unstablel |
1)
|
Sunlight, fluorescent
lighting, or other types of lighting can interfere with IR data communication.
Perform your IR data communication in an area that is not exposed
to such lighting. |
|
2)
|
Interference from the
remote control units of a TV or another appliance can interfere with
IR data communication. Keep such remote-controlled devices away from
the IR port of your computer. |
| 3)
|
Data communications problems
can result when the IR ports are not the correct distance from each
other.
The proper distance required between IR ports depends on the device
you are communicating with. See the documentation that comes with
the other device for more information.
|
| 4)
|
Perform the following
procedure to check if the Image Transfer option on your system's Wireless
Link dialog box is turned off. |
| |
1.
|
Select [ Start ]
[ Settings ]
[ Control Panel ]. |
| 2.
|
Double-click the [Wireless Link] icon. |
3.
|
Select the [Image Transfer] tab. |
| 4.
|
Uncheck the [Use Wireless Link to transfer
images from a digital camera to your computer]. |
|
| 5)
|
Are you using a screen
saver?
Data communication can be interrupted by a screen saver or other software
that forces an interrupt during data communication. In the worst case,
such an interrupt can damage your computer or Wrist Camera. Because
of this, you should always disable your screen saver whenever using
WQV Link 3.0. |
| 6)
|
Anti-virus software, file
utilities, and other resident software can generate interrupts that
interfere with or even interrupt data communication. If this happens,
quit the resident software applications. See the user documentation
that comes with your applications for information about how to quit
them. See the documentation that came with your computer or contact
the manufacturer of the software for more information. |
| 7)
|
Notebook computers and
other types of computers are equipped with power save functions, which
cut off power to the COM ports, making data communication impossible.
If this happens, turn off the power save function. For information
about checking or changing the status of your computer's power save
function, see its user documentation or contact the manufacturer.
|
|
8)
|
Is some other application
using your computer's IR port or serial port?
Data communication using WQV Link 3.0 software will not be possible
if your IR port is set up for data communication by a PDA link application
(such as ActiveSync for Windows CE), even if that application is not
currently running.
In this case, you need to disable use of IR data communication port
by the application that is occupying it.
If you are using the PAD-2B 9-pin serial IR adapter, any PDA link,
digital camera link, fax, MIDI, or other similar application software
or driver occupying a port may issue interrupts that make it impossible
for the WQV Link 3.0 software to run properly. In this case, you need
to disable use of serial port by the application that is occupying
it. |
Important!
After you set up a COM port for the PAD-2B IR adapter, other application
software that uses the same COM port may not operate properly even
after you disconnect the PAD-2B IR adapter. If this happens, open
the Control Panel's [IR Monitor], click the [Options] tab, and then
uncheck the "Enable IR Communication" option.
In this case, you will have to select (check) the "Enable IR
Communication" option again when you want to use the WQV Link
3.0 software. |
|